{
  "schemaVersion": "1.0",
  "item": {
    "slug": "blade-inspection",
    "name": "Blade Inspection",
    "source": "tencent",
    "type": "skill",
    "category": "数据分析",
    "sourceUrl": "https://clawhub.ai/Sertug17/blade-inspection",
    "canonicalUrl": "https://clawhub.ai/Sertug17/blade-inspection",
    "targetPlatform": "OpenClaw"
  },
  "install": {
    "downloadMode": "redirect",
    "downloadUrl": "/downloads/blade-inspection",
    "sourceDownloadUrl": "https://wry-manatee-359.convex.site/api/v1/download?slug=blade-inspection",
    "sourcePlatform": "tencent",
    "targetPlatform": "OpenClaw",
    "installMethod": "Manual import",
    "extraction": "Extract archive",
    "prerequisites": [
      "OpenClaw"
    ],
    "packageFormat": "ZIP package",
    "includedAssets": [
      "SKILL.md"
    ],
    "primaryDoc": "SKILL.md",
    "quickSetup": [
      "Download the package from Yavira.",
      "Extract the archive and review SKILL.md first.",
      "Import or place the package into your OpenClaw setup."
    ],
    "agentAssist": {
      "summary": "Hand the extracted package to your coding agent with a concrete install brief instead of figuring it out manually.",
      "steps": [
        "Download the package from Yavira.",
        "Extract it into a folder your agent can access.",
        "Paste one of the prompts below and point your agent at the extracted folder."
      ],
      "prompts": [
        {
          "label": "New install",
          "body": "I downloaded a skill package from Yavira. Read SKILL.md from the extracted folder and install it by following the included instructions. Tell me what you changed and call out any manual steps you could not complete."
        },
        {
          "label": "Upgrade existing",
          "body": "I downloaded an updated skill package from Yavira. Read SKILL.md from the extracted folder, compare it with my current installation, and upgrade it while preserving any custom configuration unless the package docs explicitly say otherwise. Summarize what changed and any follow-up checks I should run."
        }
      ]
    },
    "sourceHealth": {
      "source": "tencent",
      "status": "healthy",
      "reason": "direct_download_ok",
      "recommendedAction": "download",
      "checkedAt": "2026-04-23T16:43:11.935Z",
      "expiresAt": "2026-04-30T16:43:11.935Z",
      "httpStatus": 200,
      "finalUrl": "https://wry-manatee-359.convex.site/api/v1/download?slug=4claw-imageboard",
      "contentType": "application/zip",
      "probeMethod": "head",
      "details": {
        "probeUrl": "https://wry-manatee-359.convex.site/api/v1/download?slug=4claw-imageboard",
        "contentDisposition": "attachment; filename=\"4claw-imageboard-1.0.1.zip\"",
        "redirectLocation": null,
        "bodySnippet": null
      },
      "scope": "source",
      "summary": "Source download looks usable.",
      "detail": "Yavira can redirect you to the upstream package for this source.",
      "primaryActionLabel": "Download for OpenClaw",
      "primaryActionHref": "/downloads/blade-inspection"
    },
    "validation": {
      "installChecklist": [
        "Use the Yavira download entry.",
        "Review SKILL.md after the package is downloaded.",
        "Confirm the extracted package contains the expected setup assets."
      ],
      "postInstallChecks": [
        "Confirm the extracted package includes the expected docs or setup files.",
        "Validate the skill or prompts are available in your target agent workspace.",
        "Capture any manual follow-up steps the agent could not complete."
      ]
    },
    "downloadPageUrl": "https://openagent3.xyz/downloads/blade-inspection",
    "agentPageUrl": "https://openagent3.xyz/skills/blade-inspection/agent",
    "manifestUrl": "https://openagent3.xyz/skills/blade-inspection/agent.json",
    "briefUrl": "https://openagent3.xyz/skills/blade-inspection/agent.md"
  },
  "agentAssist": {
    "summary": "Hand the extracted package to your coding agent with a concrete install brief instead of figuring it out manually.",
    "steps": [
      "Download the package from Yavira.",
      "Extract it into a folder your agent can access.",
      "Paste one of the prompts below and point your agent at the extracted folder."
    ],
    "prompts": [
      {
        "label": "New install",
        "body": "I downloaded a skill package from Yavira. Read SKILL.md from the extracted folder and install it by following the included instructions. Tell me what you changed and call out any manual steps you could not complete."
      },
      {
        "label": "Upgrade existing",
        "body": "I downloaded an updated skill package from Yavira. Read SKILL.md from the extracted folder, compare it with my current installation, and upgrade it while preserving any custom configuration unless the package docs explicitly say otherwise. Summarize what changed and any follow-up checks I should run."
      }
    ]
  },
  "documentation": {
    "source": "clawhub",
    "primaryDoc": "SKILL.md",
    "sections": [
      {
        "title": "Wind Turbine Blade Inspection Intelligence",
        "body": "Evaluates blade condition from drone or ground-based visual inspection and produces a structured damage assessment across seven failure modes."
      },
      {
        "title": "When to Use",
        "body": "Load this skill when the user wants to:\n\nAssess blade health from drone inspection images or written findings\nClassify damage type and severity on a 1-5 scale per blade and per zone\nDetermine whether a turbine should continue operating, be scheduled for repair, or shut down\nGenerate a structured blade inspection report with repair recommendations"
      },
      {
        "title": "Blade Zones",
        "body": "ZoneSpanDescriptionRoot0-33%Highest structural loads, bolted connection areaMid33-66%Transition zone, moderate aerodynamic loadTip66-100%Highest velocity, most erosion-prone, lightning receptor area\n\nSurfaces: Leading Edge (LE), Trailing Edge (TE), Suction Side (SS), Pressure Side (PS)"
      },
      {
        "title": "Damage Type Definitions",
        "body": "Damage TypeDescriptionTypical LocationSurface crackGelcoat or laminate cracks, linear fracturesLE, TE, root transitionErosion / wearMaterial loss, pitting, rougheningLE tip zoneLightning damageBurn marks, punctures, receptor damageTip, receptor areaLamination/structuralDelamination, fiber exposure, buckling, dentsAny zoneDebondingBond line separation at LE, TE, or shear webLE, TE, internalIce accumulationIce buildup on surface or edgesAny zoneGeneral visual anomalyDiscoloration, contamination, coating lossAny zone"
      },
      {
        "title": "Severity Scale",
        "body": "SeverityLabelDescriptionAction1HealthyNo damage or cosmetic marks onlyContinue normal operation2MinorEarly erosion, superficial cracks, coating lossIncrease inspection frequency3ModerateGelcoat breach, early debonding, defined damageRepair within 1-3 months4SignificantStructural involvement, active debonding, lightningRepair within 2-4 weeks5CriticalFiber exposure, structural breach, delaminationImmediate shutdown required"
      },
      {
        "title": "Procedure",
        "body": "Collect inputs: blade IDs, inspection method, findings per blade per zone per surface.\nClassify each finding by damage type.\nAssign severity per finding using the severity scale.\nDetermine overall blade severity as the highest finding for that blade.\nDetermine turbine-level severity as the highest across all blades.\nApply damage-specific rules:\n\nLightning damage: minimum Severity 4 until OEM confirms otherwise.\nDebonding at LE or TE over 300 mm: escalate to Severity 4.\nAny confirmed fiber exposure: minimum Severity 4.\nErosion with full gelcoat loss over 500 mm span at tip: Severity 4.\nActive ice accumulation: always Severity 4.\n\n\nGenerate output report using the format below."
      },
      {
        "title": "Output Format",
        "body": "=== BLADE INSPECTION REPORT ===\n\nASSET        : [Turbine ID]\nSITE         : [Site name]\nINSPECTION   : [Date / Method]\nBLADES       : [Number inspected]\n\nBLADE [ID]:\nZone/Surface  : [e.g., Tip / Leading Edge]\nDamage Type   : [e.g., Erosion]\nDescription   : [e.g., Deep pitting ~600 mm span, gelcoat fully lost]\nSeverity      : [1-5] - [Label]\n\nBLADE [ID] OVERALL SEVERITY: [1-5] - [Label]\n\nTURBINE-LEVEL SEVERITY : [1-5] - [Label]\nSHUTDOWN RECOMMENDATION: [Yes / No / Conditional]\n\nREPAIR PRIORITY:\n\n[e.g., Blade 2 tip LE erosion - schedule LEP repair within 6 weeks]\n\nMONITORING STRATEGY:\n\n[e.g., Monthly drone re-inspection for all blades]\n\nESCALATION TRIGGERS:\n\n[e.g., Debond length exceeds 500 mm - shutdown for repair]\n[e.g., SCADA vibration or imbalance alarms - ground turbine]"
      },
      {
        "title": "Damage-Specific Guidance",
        "body": "Erosion: Progresses from roughening to pitting to gelcoat loss to fiber exposure. Repair with Leading Edge Protection (LEP) tape or coating. Severity 3-4 causes measurable energy production loss.\n\nLightning: Always notify OEM. Minor visible damage may hide internal delamination. Do not assume safe to operate until specialist confirms.\n\nDebonding: LE debonding causes aerodynamic noise and vibration. TE debonding starts at tip and progresses toward root. Bond line gap over 300 mm is Severity 4.\n\nLamination/Structural: Fiber exposure is always Severity 4 minimum. Dents or buckling without fiber exposure is Severity 3.\n\nIce: Active ice requires immediate grounding due to rotor imbalance and ice throw risk. After melting, inspect surface for underlying damage."
      },
      {
        "title": "Pitfalls",
        "body": "Do not classify erosion from low-resolution images. Ask for close-up zone-specific photos.\nLightning damage is always higher priority than it looks. Treat as Severity 4 until proven otherwise.\nDebonding can be invisible from drone imagery. If SCADA shows imbalance alarms, flag potential hidden debonding.\nActive ice is a safety hazard. Recommend immediate grounding.\nAssess each blade independently. Damage distribution is rarely uniform across all three blades."
      },
      {
        "title": "Verification",
        "body": "After generating the report, confirm with the user:\n\nDoes the severity match the inspector's on-site assessment?\nAre all three blades accounted for?\nAre there SCADA alarms (vibration, imbalance, power curve deviation) correlating with findings?\nIs there a previous inspection report for trend comparison?"
      }
    ],
    "body": "Wind Turbine Blade Inspection Intelligence\n\nEvaluates blade condition from drone or ground-based visual inspection and produces a structured damage assessment across seven failure modes.\n\nWhen to Use\n\nLoad this skill when the user wants to:\n\nAssess blade health from drone inspection images or written findings\nClassify damage type and severity on a 1-5 scale per blade and per zone\nDetermine whether a turbine should continue operating, be scheduled for repair, or shut down\nGenerate a structured blade inspection report with repair recommendations\nBlade Zones\nZone\tSpan\tDescription\nRoot\t0-33%\tHighest structural loads, bolted connection area\nMid\t33-66%\tTransition zone, moderate aerodynamic load\nTip\t66-100%\tHighest velocity, most erosion-prone, lightning receptor area\n\nSurfaces: Leading Edge (LE), Trailing Edge (TE), Suction Side (SS), Pressure Side (PS)\n\nDamage Type Definitions\nDamage Type\tDescription\tTypical Location\nSurface crack\tGelcoat or laminate cracks, linear fractures\tLE, TE, root transition\nErosion / wear\tMaterial loss, pitting, roughening\tLE tip zone\nLightning damage\tBurn marks, punctures, receptor damage\tTip, receptor area\nLamination/structural\tDelamination, fiber exposure, buckling, dents\tAny zone\nDebonding\tBond line separation at LE, TE, or shear web\tLE, TE, internal\nIce accumulation\tIce buildup on surface or edges\tAny zone\nGeneral visual anomaly\tDiscoloration, contamination, coating loss\tAny zone\nSeverity Scale\nSeverity\tLabel\tDescription\tAction\n1\tHealthy\tNo damage or cosmetic marks only\tContinue normal operation\n2\tMinor\tEarly erosion, superficial cracks, coating loss\tIncrease inspection frequency\n3\tModerate\tGelcoat breach, early debonding, defined damage\tRepair within 1-3 months\n4\tSignificant\tStructural involvement, active debonding, lightning\tRepair within 2-4 weeks\n5\tCritical\tFiber exposure, structural breach, delamination\tImmediate shutdown required\nProcedure\nCollect inputs: blade IDs, inspection method, findings per blade per zone per surface.\nClassify each finding by damage type.\nAssign severity per finding using the severity scale.\nDetermine overall blade severity as the highest finding for that blade.\nDetermine turbine-level severity as the highest across all blades.\nApply damage-specific rules:\nLightning damage: minimum Severity 4 until OEM confirms otherwise.\nDebonding at LE or TE over 300 mm: escalate to Severity 4.\nAny confirmed fiber exposure: minimum Severity 4.\nErosion with full gelcoat loss over 500 mm span at tip: Severity 4.\nActive ice accumulation: always Severity 4.\nGenerate output report using the format below.\nOutput Format\n\n=== BLADE INSPECTION REPORT ===\n\nASSET : [Turbine ID] SITE : [Site name] INSPECTION : [Date / Method] BLADES : [Number inspected]\n\nBLADE [ID]: Zone/Surface : [e.g., Tip / Leading Edge] Damage Type : [e.g., Erosion] Description : [e.g., Deep pitting ~600 mm span, gelcoat fully lost] Severity : [1-5] - [Label]\n\nBLADE [ID] OVERALL SEVERITY: [1-5] - [Label]\n\nTURBINE-LEVEL SEVERITY : [1-5] - [Label] SHUTDOWN RECOMMENDATION: [Yes / No / Conditional]\n\nREPAIR PRIORITY:\n\n[e.g., Blade 2 tip LE erosion - schedule LEP repair within 6 weeks]\n\nMONITORING STRATEGY:\n\n[e.g., Monthly drone re-inspection for all blades]\n\nESCALATION TRIGGERS:\n\n[e.g., Debond length exceeds 500 mm - shutdown for repair]\n[e.g., SCADA vibration or imbalance alarms - ground turbine]\nDamage-Specific Guidance\n\nErosion: Progresses from roughening to pitting to gelcoat loss to fiber exposure. Repair with Leading Edge Protection (LEP) tape or coating. Severity 3-4 causes measurable energy production loss.\n\nLightning: Always notify OEM. Minor visible damage may hide internal delamination. Do not assume safe to operate until specialist confirms.\n\nDebonding: LE debonding causes aerodynamic noise and vibration. TE debonding starts at tip and progresses toward root. Bond line gap over 300 mm is Severity 4.\n\nLamination/Structural: Fiber exposure is always Severity 4 minimum. Dents or buckling without fiber exposure is Severity 3.\n\nIce: Active ice requires immediate grounding due to rotor imbalance and ice throw risk. After melting, inspect surface for underlying damage.\n\nPitfalls\nDo not classify erosion from low-resolution images. Ask for close-up zone-specific photos.\nLightning damage is always higher priority than it looks. Treat as Severity 4 until proven otherwise.\nDebonding can be invisible from drone imagery. If SCADA shows imbalance alarms, flag potential hidden debonding.\nActive ice is a safety hazard. Recommend immediate grounding.\nAssess each blade independently. Damage distribution is rarely uniform across all three blades.\nVerification\n\nAfter generating the report, confirm with the user:\n\nDoes the severity match the inspector's on-site assessment?\nAre all three blades accounted for?\nAre there SCADA alarms (vibration, imbalance, power curve deviation) correlating with findings?\nIs there a previous inspection report for trend comparison?"
  },
  "trust": {
    "sourceLabel": "tencent",
    "provenanceUrl": "https://clawhub.ai/Sertug17/blade-inspection",
    "publisherUrl": "https://clawhub.ai/Sertug17/blade-inspection",
    "owner": "Sertug17",
    "version": "1.0.0",
    "license": null,
    "verificationStatus": "Indexed source record"
  },
  "links": {
    "detailUrl": "https://openagent3.xyz/skills/blade-inspection",
    "downloadUrl": "https://openagent3.xyz/downloads/blade-inspection",
    "agentUrl": "https://openagent3.xyz/skills/blade-inspection/agent",
    "manifestUrl": "https://openagent3.xyz/skills/blade-inspection/agent.json",
    "briefUrl": "https://openagent3.xyz/skills/blade-inspection/agent.md"
  }
}