{
  "schemaVersion": "1.0",
  "item": {
    "slug": "gearbox",
    "name": "Gearbox",
    "source": "tencent",
    "type": "skill",
    "category": "AI 智能",
    "sourceUrl": "https://clawhub.ai/Sertug17/gearbox",
    "canonicalUrl": "https://clawhub.ai/Sertug17/gearbox",
    "targetPlatform": "OpenClaw"
  },
  "install": {
    "downloadMode": "redirect",
    "downloadUrl": "/downloads/gearbox",
    "sourceDownloadUrl": "https://wry-manatee-359.convex.site/api/v1/download?slug=gearbox",
    "sourcePlatform": "tencent",
    "targetPlatform": "OpenClaw",
    "installMethod": "Manual import",
    "extraction": "Extract archive",
    "prerequisites": [
      "OpenClaw"
    ],
    "packageFormat": "ZIP package",
    "includedAssets": [
      "SKILL.md"
    ],
    "primaryDoc": "SKILL.md",
    "quickSetup": [
      "Download the package from Yavira.",
      "Extract the archive and review SKILL.md first.",
      "Import or place the package into your OpenClaw setup."
    ],
    "agentAssist": {
      "summary": "Hand the extracted package to your coding agent with a concrete install brief instead of figuring it out manually.",
      "steps": [
        "Download the package from Yavira.",
        "Extract it into a folder your agent can access.",
        "Paste one of the prompts below and point your agent at the extracted folder."
      ],
      "prompts": [
        {
          "label": "New install",
          "body": "I downloaded a skill package from Yavira. Read SKILL.md from the extracted folder and install it by following the included instructions. Tell me what you changed and call out any manual steps you could not complete."
        },
        {
          "label": "Upgrade existing",
          "body": "I downloaded an updated skill package from Yavira. Read SKILL.md from the extracted folder, compare it with my current installation, and upgrade it while preserving any custom configuration unless the package docs explicitly say otherwise. Summarize what changed and any follow-up checks I should run."
        }
      ]
    },
    "sourceHealth": {
      "source": "tencent",
      "status": "healthy",
      "reason": "direct_download_ok",
      "recommendedAction": "download",
      "checkedAt": "2026-04-30T16:55:25.780Z",
      "expiresAt": "2026-05-07T16:55:25.780Z",
      "httpStatus": 200,
      "finalUrl": "https://wry-manatee-359.convex.site/api/v1/download?slug=network",
      "contentType": "application/zip",
      "probeMethod": "head",
      "details": {
        "probeUrl": "https://wry-manatee-359.convex.site/api/v1/download?slug=network",
        "contentDisposition": "attachment; filename=\"network-1.0.0.zip\"",
        "redirectLocation": null,
        "bodySnippet": null
      },
      "scope": "source",
      "summary": "Source download looks usable.",
      "detail": "Yavira can redirect you to the upstream package for this source.",
      "primaryActionLabel": "Download for OpenClaw",
      "primaryActionHref": "/downloads/gearbox"
    },
    "validation": {
      "installChecklist": [
        "Use the Yavira download entry.",
        "Review SKILL.md after the package is downloaded.",
        "Confirm the extracted package contains the expected setup assets."
      ],
      "postInstallChecks": [
        "Confirm the extracted package includes the expected docs or setup files.",
        "Validate the skill or prompts are available in your target agent workspace.",
        "Capture any manual follow-up steps the agent could not complete."
      ]
    },
    "downloadPageUrl": "https://openagent3.xyz/downloads/gearbox",
    "agentPageUrl": "https://openagent3.xyz/skills/gearbox/agent",
    "manifestUrl": "https://openagent3.xyz/skills/gearbox/agent.json",
    "briefUrl": "https://openagent3.xyz/skills/gearbox/agent.md"
  },
  "agentAssist": {
    "summary": "Hand the extracted package to your coding agent with a concrete install brief instead of figuring it out manually.",
    "steps": [
      "Download the package from Yavira.",
      "Extract it into a folder your agent can access.",
      "Paste one of the prompts below and point your agent at the extracted folder."
    ],
    "prompts": [
      {
        "label": "New install",
        "body": "I downloaded a skill package from Yavira. Read SKILL.md from the extracted folder and install it by following the included instructions. Tell me what you changed and call out any manual steps you could not complete."
      },
      {
        "label": "Upgrade existing",
        "body": "I downloaded an updated skill package from Yavira. Read SKILL.md from the extracted folder, compare it with my current installation, and upgrade it while preserving any custom configuration unless the package docs explicitly say otherwise. Summarize what changed and any follow-up checks I should run."
      }
    ]
  },
  "documentation": {
    "source": "clawhub",
    "primaryDoc": "SKILL.md",
    "sections": [
      {
        "title": "Wind Turbine Gearbox Intelligence",
        "body": "Evaluates gearbox condition using five input parameters and produces a structured maintenance report."
      },
      {
        "title": "When to Use",
        "body": "Load this skill when the user wants to:\n\nAssess gearbox health from on-site inspection or sensor data\nClassify damage severity on a 1-5 scale\nDetermine whether a turbine should be shut down or kept running under monitoring\nGenerate a structured maintenance or escalation plan"
      },
      {
        "title": "Quick Reference",
        "body": "Input ParameterWhat to CollectVisual inspectionSurface cracks, pitting, spalling, discoloration, debrisOil iron (Fe ppm)Iron particle concentration in gear oil (ppm)Temperature (C)Bearing/gear temperature, normalized to baselineVibrationRMS or peak-to-peak acceleration (g), frequency anomaliesAcoustic / SoundNoise type: grinding, knocking, whining, clicking"
      },
      {
        "title": "Fault Thresholds (Reference)",
        "body": "ParameterNormalWarningCriticalOil Fe (ppm)< 100100 - 300> 300Temp above baseline< 5 C5 - 15 C> 15 CVibration RMS (g)< 0.50.5 - 1.5> 1.5AcousticNo anomalyIntermittentContinuousVisualClean surfaceMinor pittingSpalling/crack"
      },
      {
        "title": "Common Failure Modes",
        "body": "Failure ModeTypical IndicatorsMicropittingHigh Fe ppm, slight vibration increase, no visible cracksSpallingHigh Fe ppm, elevated vibration, visible surface damageFatigue crackKnocking sound, vibration spike at gear mesh frequencyBearing wearWhining noise, high temperature, broadband vibration increaseOil contaminationVery high Fe ppm, discolored oil, possible foaming"
      },
      {
        "title": "Procedure",
        "body": "Collect inputs across all five parameters. If any are unavailable, note as \"not measured\" and proceed.\nEvaluate each parameter against the thresholds table. Flag Warning or Critical zones.\nCross-correlate symptoms:\n\nFe ppm + vibration increase → wear / spalling progression\nKnocking sound + vibration spike → fatigue crack\nTemperature + whining sound → bearing failure\nMultiple Critical flags → Severity 5\n\n\nAssign severity:\n\n1 Healthy: All parameters normal. No action required.\n2 Early wear: 1-2 parameters in warning zone. Increase monitoring frequency.\n3 Moderate damage: 2-3 parameters in warning/critical. Inspect within 2 weeks.\n4 Significant damage: Multiple critical flags. Plan shutdown within 48-72 hours.\n5 Critical: Imminent failure risk. Immediate shutdown required.\n\n\nDetermine root cause from the failure modes table.\nGenerate the output report using the format below."
      },
      {
        "title": "Output Format",
        "body": "=== GEARBOX HEALTH REPORT ===\n\nROOT CAUSE : [e.g., Progressive spalling on intermediate shaft gear]\nSEVERITY   : [1-5] - [Healthy / Early Wear / Moderate / Significant / Critical]\nSHUTDOWN   : [Yes / No / Conditional]\n\nMONITORING STRATEGY:\n\n[e.g., Repeat oil sample in 72 hours]\n[e.g., Daily vibration trend monitoring for 1 week]\n\nESCALATION TRIGGERS:\n\n[e.g., Fe ppm exceeds 400 - immediate shutdown]\n[e.g., Vibration RMS exceeds 2.0 g - immediate shutdown]"
      },
      {
        "title": "Pitfalls",
        "body": "Never assign Severity 5 based on one parameter alone. Cross-validate with at least two sources.\nTemperature readings can be misleading in extreme ambient conditions. Ask for baseline-normalized values.\nAcoustic descriptions are subjective. Ask for noise type and whether continuous or intermittent.\nIf sensor data is unavailable, rely on visual and oil condition as primary indicators.\nDo not conflate oil change interval with oil health. New oil can still show high Fe ppm."
      },
      {
        "title": "Verification",
        "body": "After generating the report, confirm with the user:\n\nDoes the severity match their on-site observations?\nAre escalation thresholds feasible for their monitoring setup?\nAre there additional data points (CMS trending, historical Fe ppm) that could refine the assessment?"
      }
    ],
    "body": "Wind Turbine Gearbox Intelligence\n\nEvaluates gearbox condition using five input parameters and produces a structured maintenance report.\n\nWhen to Use\n\nLoad this skill when the user wants to:\n\nAssess gearbox health from on-site inspection or sensor data\nClassify damage severity on a 1-5 scale\nDetermine whether a turbine should be shut down or kept running under monitoring\nGenerate a structured maintenance or escalation plan\nQuick Reference\nInput Parameter\tWhat to Collect\nVisual inspection\tSurface cracks, pitting, spalling, discoloration, debris\nOil iron (Fe ppm)\tIron particle concentration in gear oil (ppm)\nTemperature (C)\tBearing/gear temperature, normalized to baseline\nVibration\tRMS or peak-to-peak acceleration (g), frequency anomalies\nAcoustic / Sound\tNoise type: grinding, knocking, whining, clicking\nFault Thresholds (Reference)\nParameter\tNormal\tWarning\tCritical\nOil Fe (ppm)\t< 100\t100 - 300\t> 300\nTemp above baseline\t< 5 C\t5 - 15 C\t> 15 C\nVibration RMS (g)\t< 0.5\t0.5 - 1.5\t> 1.5\nAcoustic\tNo anomaly\tIntermittent\tContinuous\nVisual\tClean surface\tMinor pitting\tSpalling/crack\nCommon Failure Modes\nFailure Mode\tTypical Indicators\nMicropitting\tHigh Fe ppm, slight vibration increase, no visible cracks\nSpalling\tHigh Fe ppm, elevated vibration, visible surface damage\nFatigue crack\tKnocking sound, vibration spike at gear mesh frequency\nBearing wear\tWhining noise, high temperature, broadband vibration increase\nOil contamination\tVery high Fe ppm, discolored oil, possible foaming\nProcedure\nCollect inputs across all five parameters. If any are unavailable, note as \"not measured\" and proceed.\nEvaluate each parameter against the thresholds table. Flag Warning or Critical zones.\nCross-correlate symptoms:\nFe ppm + vibration increase → wear / spalling progression\nKnocking sound + vibration spike → fatigue crack\nTemperature + whining sound → bearing failure\nMultiple Critical flags → Severity 5\nAssign severity:\n1 Healthy: All parameters normal. No action required.\n2 Early wear: 1-2 parameters in warning zone. Increase monitoring frequency.\n3 Moderate damage: 2-3 parameters in warning/critical. Inspect within 2 weeks.\n4 Significant damage: Multiple critical flags. Plan shutdown within 48-72 hours.\n5 Critical: Imminent failure risk. Immediate shutdown required.\nDetermine root cause from the failure modes table.\nGenerate the output report using the format below.\nOutput Format\n\n=== GEARBOX HEALTH REPORT ===\n\nROOT CAUSE : [e.g., Progressive spalling on intermediate shaft gear] SEVERITY : [1-5] - [Healthy / Early Wear / Moderate / Significant / Critical] SHUTDOWN : [Yes / No / Conditional]\n\nMONITORING STRATEGY:\n\n[e.g., Repeat oil sample in 72 hours]\n[e.g., Daily vibration trend monitoring for 1 week]\n\nESCALATION TRIGGERS:\n\n[e.g., Fe ppm exceeds 400 - immediate shutdown]\n[e.g., Vibration RMS exceeds 2.0 g - immediate shutdown]\nPitfalls\nNever assign Severity 5 based on one parameter alone. Cross-validate with at least two sources.\nTemperature readings can be misleading in extreme ambient conditions. Ask for baseline-normalized values.\nAcoustic descriptions are subjective. Ask for noise type and whether continuous or intermittent.\nIf sensor data is unavailable, rely on visual and oil condition as primary indicators.\nDo not conflate oil change interval with oil health. New oil can still show high Fe ppm.\nVerification\n\nAfter generating the report, confirm with the user:\n\nDoes the severity match their on-site observations?\nAre escalation thresholds feasible for their monitoring setup?\nAre there additional data points (CMS trending, historical Fe ppm) that could refine the assessment?"
  },
  "trust": {
    "sourceLabel": "tencent",
    "provenanceUrl": "https://clawhub.ai/Sertug17/gearbox",
    "publisherUrl": "https://clawhub.ai/Sertug17/gearbox",
    "owner": "Sertug17",
    "version": "1.0.0",
    "license": null,
    "verificationStatus": "Indexed source record"
  },
  "links": {
    "detailUrl": "https://openagent3.xyz/skills/gearbox",
    "downloadUrl": "https://openagent3.xyz/downloads/gearbox",
    "agentUrl": "https://openagent3.xyz/skills/gearbox/agent",
    "manifestUrl": "https://openagent3.xyz/skills/gearbox/agent.json",
    "briefUrl": "https://openagent3.xyz/skills/gearbox/agent.md"
  }
}