# Send Quality Manager Qms Iso13485 to your agent
Hand the extracted package to your coding agent with a concrete install brief instead of figuring it out manually.
## Fast path
- Download the package from Yavira.
- Extract it into a folder your agent can access.
- Paste one of the prompts below and point your agent at the extracted folder.
## Suggested prompts
### New install

```text
I downloaded a skill package from Yavira. Read SKILL.md from the extracted folder and install it by following the included instructions. Tell me what you changed and call out any manual steps you could not complete.
```
### Upgrade existing

```text
I downloaded an updated skill package from Yavira. Read SKILL.md from the extracted folder, compare it with my current installation, and upgrade it while preserving any custom configuration unless the package docs explicitly say otherwise. Summarize what changed and any follow-up checks I should run.
```
## Machine-readable fields
```json
{
  "schemaVersion": "1.0",
  "item": {
    "slug": "quality-manager-qms-iso13485",
    "name": "Quality Manager Qms Iso13485",
    "source": "tencent",
    "type": "skill",
    "category": "安全合规",
    "sourceUrl": "https://clawhub.ai/alirezarezvani/quality-manager-qms-iso13485",
    "canonicalUrl": "https://clawhub.ai/alirezarezvani/quality-manager-qms-iso13485",
    "targetPlatform": "OpenClaw"
  },
  "install": {
    "downloadUrl": "/downloads/quality-manager-qms-iso13485",
    "sourceDownloadUrl": "https://wry-manatee-359.convex.site/api/v1/download?slug=quality-manager-qms-iso13485",
    "sourcePlatform": "tencent",
    "targetPlatform": "OpenClaw",
    "packageFormat": "ZIP package",
    "primaryDoc": "SKILL.md",
    "includedAssets": [
      "SKILL.md",
      "references/iso13485-clause-requirements.md",
      "references/qms-process-templates.md",
      "scripts/qms_audit_checklist.py"
    ],
    "downloadMode": "redirect",
    "sourceHealth": {
      "source": "tencent",
      "status": "healthy",
      "reason": "direct_download_ok",
      "recommendedAction": "download",
      "checkedAt": "2026-04-23T16:43:11.935Z",
      "expiresAt": "2026-04-30T16:43:11.935Z",
      "httpStatus": 200,
      "finalUrl": "https://wry-manatee-359.convex.site/api/v1/download?slug=4claw-imageboard",
      "contentType": "application/zip",
      "probeMethod": "head",
      "details": {
        "probeUrl": "https://wry-manatee-359.convex.site/api/v1/download?slug=4claw-imageboard",
        "contentDisposition": "attachment; filename=\"4claw-imageboard-1.0.1.zip\"",
        "redirectLocation": null,
        "bodySnippet": null
      },
      "scope": "source",
      "summary": "Source download looks usable.",
      "detail": "Yavira can redirect you to the upstream package for this source.",
      "primaryActionLabel": "Download for OpenClaw",
      "primaryActionHref": "/downloads/quality-manager-qms-iso13485"
    },
    "validation": {
      "installChecklist": [
        "Use the Yavira download entry.",
        "Review SKILL.md after the package is downloaded.",
        "Confirm the extracted package contains the expected setup assets."
      ],
      "postInstallChecks": [
        "Confirm the extracted package includes the expected docs or setup files.",
        "Validate the skill or prompts are available in your target agent workspace.",
        "Capture any manual follow-up steps the agent could not complete."
      ]
    }
  },
  "links": {
    "detailUrl": "https://openagent3.xyz/skills/quality-manager-qms-iso13485",
    "downloadUrl": "https://openagent3.xyz/downloads/quality-manager-qms-iso13485",
    "agentUrl": "https://openagent3.xyz/skills/quality-manager-qms-iso13485/agent",
    "manifestUrl": "https://openagent3.xyz/skills/quality-manager-qms-iso13485/agent.json",
    "briefUrl": "https://openagent3.xyz/skills/quality-manager-qms-iso13485/agent.md"
  }
}
```
## Documentation

### Quality Manager - QMS ISO 13485 Specialist

ISO 13485:2016 Quality Management System implementation, maintenance, and certification support for medical device organizations.

### Table of Contents

QMS Implementation Workflow
Document Control Workflow
Internal Audit Workflow
Process Validation Workflow
Supplier Qualification Workflow
QMS Process Reference
Decision Frameworks
Tools and References

### QMS Implementation Workflow

Implement ISO 13485:2016 compliant quality management system from gap analysis through certification.

### Workflow: Initial QMS Implementation

Conduct gap analysis against ISO 13485:2016 requirements
Document current state vs. required state for each clause
Prioritize gaps by:

Regulatory criticality
Risk to product safety
Resource requirements


Develop implementation roadmap with milestones
Establish Quality Manual per Clause 4.2.2:

QMS scope with justified exclusions
Process interactions
Procedure references


Create required documented procedures — see Mandatory Documented Procedures for the full list
Deploy processes with training
Validation: Gap analysis complete; Quality Manual approved; all required procedures documented and trained

Use the Gap Analysis Matrix template in qms-process-templates.md to document clause-by-clause current state, gaps, priority, and actions.

### QMS Structure

LevelDocument TypeExample1Quality ManualQM-0012ProceduresSOP-02-0013Work InstructionsWI-06-0124RecordsTraining records

### Document Control Workflow

Establish and maintain document control per ISO 13485 Clause 4.2.3.

### Workflow: Document Creation and Approval

Identify need for new document or revision
Assign document number per numbering convention:

Format: [TYPE]-[AREA]-[SEQUENCE]-[REV]
Example: SOP-02-001-01


Draft document using approved template
Route for review to subject matter experts
Collect and address review comments
Obtain required approvals based on document type
Update Document Master List
Validation: Document numbered correctly; all reviewers signed; Master List updated

### Document Numbering Convention

PrefixDocument TypeApproval AuthorityQMQuality ManualManagement Rep + CEOPOLPolicyDepartment Head + QASOPProcedureProcess Owner + QAWIWork InstructionSupervisor + QATFTemplate/FormProcess OwnerSPECSpecificationEngineering + QA

### Area Codes

CodeAreaExamples01Quality ManagementQuality Manual, policy02Document ControlThis procedure03TrainingCompetency procedures04DesignDesign control05PurchasingSupplier management06ProductionManufacturing07Quality ControlInspection, testing08CAPACorrective actions

### Document Change Control

Change TypeApproval LevelExamplesAdministrativeDocument ControlTypos, formattingMinorProcess Owner + QAClarificationsMajorFull review cycleProcess changesEmergencyExpedited + retrospectiveSafety issues

### Document Review Schedule

Document TypeReview PeriodTrigger for Unscheduled ReviewQuality ManualAnnualOrganizational changeProceduresAnnualAudit finding, regulation changeWork Instructions2 yearsProcess changeForms2 yearsUser feedback

### Internal Audit Workflow

Plan and execute internal audits per ISO 13485 Clause 8.2.4.

### Workflow: Annual Audit Program

Identify processes and areas requiring audit coverage
Assess risk factors for audit frequency:

Previous audit findings
Regulatory changes
Process changes
Complaint trends


Assign qualified auditors (independent of area audited)
Develop annual audit schedule
Obtain management approval
Communicate schedule to process owners
Track completion and reschedule as needed
Validation: All processes covered; auditors qualified and independent; schedule approved

Use the Audit Program Template in qms-process-templates.md to schedule audits by clause and quarter across processes such as Document Control (4.2.3/4.2.4), Management Review (5.6), Design Control (7.3), Production (7.5), and CAPA (8.5.2/8.5.3).

### Workflow: Individual Audit Execution

Prepare audit plan with scope, criteria, and schedule
Notify auditee minimum 1 week prior
Review procedures and previous audit results
Prepare audit checklist
Conduct opening meeting
Collect evidence through:

Document review
Record sampling
Process observation
Personnel interviews


Classify findings:

Major NC: Absence or breakdown of system
Minor NC: Single lapse or deviation
Observation: Risk of future NC


Conduct closing meeting
Issue audit report within 5 business days
Validation: All checklist items addressed; findings supported by evidence; report distributed

### Auditor Qualification Requirements

CriterionRequirementTrainingISO 13485 awareness + auditor trainingExperienceMinimum 1 audit as observerIndependenceNot auditing own work areaCompetenceUnderstanding of audited process

### Finding Classification Guide

ClassificationCriteriaResponse TimeMajor NCSystem absence, total breakdown, regulatory violation30 days for CAPAMinor NCSingle instance, partial compliance60 days for CAPAObservationPotential risk, improvement opportunityTrack in next audit

### Process Validation Workflow

Validate special processes per ISO 13485 Clause 7.5.6.

### Workflow: Process Validation Protocol

Identify processes requiring validation:

Output cannot be verified by inspection
Deficiencies appear only in use
Sterilization, welding, sealing, software


Form validation team with subject matter experts
Write validation protocol including:

Process description and parameters
Equipment and materials
Acceptance criteria
Statistical approach


Execute IQ: verify equipment installed correctly and document specifications
Execute OQ: test parameter ranges and verify process control
Execute PQ: run production conditions and verify output meets requirements
Write validation report with conclusions
Validation: IQ/OQ/PQ complete; acceptance criteria met; validation report approved

### Validation Documentation Requirements

PhaseContentEvidenceProtocolObjectives, methods, criteriaApproved protocolIQEquipment verificationInstallation recordsOQParameter verificationTest resultsPQPerformance verificationProduction dataReportSummary, conclusionsApproval signatures

### Revalidation Triggers

TriggerAction RequiredEquipment changeAssess impact, revalidate affected phasesParameter changeOQ and PQ minimumMaterial changeAssess impact, PQ minimumProcess failureFull revalidationPeriodicPer validation schedule (typically 3 years)

### Special Process Examples

ProcessValidation StandardCritical ParametersEO SterilizationISO 11135Temperature, humidity, EO concentration, timeSteam SterilizationISO 17665Temperature, pressure, timeRadiation SterilizationISO 11137Dose, dose uniformitySealingInternalTemperature, pressure, dwell timeWeldingISO 11607Heat, pressure, speed

### Supplier Qualification Workflow

Evaluate and approve suppliers per ISO 13485 Clause 7.4.

### Workflow: New Supplier Qualification

Identify supplier category:

Category A: Critical (affects safety/performance)
Category B: Major (affects quality)
Category C: Minor (indirect impact)


Request supplier information:

Quality certifications
Product specifications
Quality history


Evaluate supplier based on:

Quality system (ISO certification)
Technical capability
Quality history
Financial stability


For Category A suppliers:

Conduct on-site audit
Require quality agreement


Calculate qualification score
Make approval decision:



80: Approved


60-80: Conditional approval
<60: Not approved


Add to Approved Supplier List
Validation: Evaluation criteria scored; qualification records complete; supplier categorized

### Supplier Evaluation Criteria

CriterionWeightScoringQuality System30%ISO 13485=30, ISO 9001=20, Documented=10, None=0Quality History25%Reject rate: <1%=25, 1-3%=15, >3%=0Delivery20%On-time: >95%=20, 90-95%=10, <90%=0Technical Capability15%Exceeds=15, Meets=10, Marginal=5Financial Stability10%Strong=10, Adequate=5, Questionable=0

### Supplier Category Requirements

CategoryQualificationMonitoringAgreementA - CriticalOn-site auditAnnual reviewQuality agreementB - MajorQuestionnaireSemi-annual reviewQuality requirementsC - MinorAssessmentIssue-basedStandard terms

### Supplier Performance Metrics

MetricTargetCalculationAccept Rate>98%(Accepted lots / Total lots) × 100On-Time Delivery>95%(On-time / Total orders) × 100Response Time<5 daysAverage days to resolve issuesDocumentation100%(Complete CoCs / Required CoCs) × 100

### QMS Process Reference

For detailed requirements and audit questions for each ISO 13485:2016 clause, see iso13485-clause-requirements.md.

### Management Review Required Inputs (Clause 5.6.2)

InputSourcePrepared ByAudit resultsInternal and external auditsQA ManagerCustomer feedbackComplaints, surveysCustomer QualityProcess performanceProcess metricsProcess OwnersProduct conformityInspection data, NCsQC ManagerCAPA statusCAPA systemCAPA OfficerPrevious actionsPrior review recordsQMRChanges affecting QMSRegulatory, organizationalRA ManagerRecommendationsAll sourcesAll Managers

### Record Retention Requirements

Record TypeMinimum RetentionRegulatory BasisDevice Master RecordLife of device + 2 years21 CFR 820.181Device History RecordLife of device + 2 years21 CFR 820.184Design History FileLife of device + 2 years21 CFR 820.30Complaint RecordsLife of device + 2 years21 CFR 820.198Training RecordsEmployment + 3 yearsBest practiceAudit Records7 yearsBest practiceCAPA Records7 yearsBest practiceCalibration RecordsEquipment life + 2 yearsBest practice

### Exclusion Justification (Clause 4.2.2)

ClausePermissible ExclusionJustification Required6.4.2Contamination controlProduct not affected by contamination7.3Design and developmentOrganization does not design products7.5.2Product cleanlinessNo cleanliness requirements7.5.3InstallationNo installation activities7.5.4ServicingNo servicing activities7.5.5Sterile productsNo sterile products

### Nonconformity Disposition Decision Tree

Nonconforming Product Identified
            │
            ▼
    Can it be reworked?
            │
       Yes──┴──No
        │       │
        ▼       ▼
    Is rework     Can it be used
    procedure     as is?
    available?        │
        │        Yes──┴──No
    Yes─┴─No     │       │
     │    │     ▼       ▼
     ▼    ▼  Concession  Scrap or
  Rework  Create    approval    return to
  per SOP  rework    needed?    supplier
          procedure     │
                    Yes─┴─No
                     │    │
                     ▼    ▼
                 Customer  Use as is
                 approval  with MRB
                          approval

### CAPA Initiation Criteria

SourceAutomatic CAPAEvaluate for CAPACustomer complaintSafety-relatedAll othersExternal auditMajor NCMinor NCInternal auditMajor NCRepeat minor NCProduct NCField failureTrend exceeds thresholdProcess deviationSafety impactRepeated deviations

### Scripts

ToolPurposeUsageqms_audit_checklist.pyGenerate audit checklists by clause or processpython qms_audit_checklist.py --help

Audit Checklist Generator Features:

Generate clause-specific checklists (e.g., --clause 7.3)
Generate process-based checklists (e.g., --process design-control)
Full system audit checklist (--audit-type system)
Text or JSON output formats
Interactive mode for guided selection

### References

DocumentContentiso13485-clause-requirements.mdDetailed requirements for each ISO 13485:2016 clause with audit questionsqms-process-templates.mdReady-to-use templates for gap analysis, audit program, document control, CAPA, supplier, training

### Quick Reference: Mandatory Documented Procedures

ProcedureClauseKey ElementsDocument Control4.2.3Approval, distribution, obsolete controlRecord Control4.2.4Identification, retention, disposalInternal Audit8.2.4Program, auditor qualification, reportingNC Product Control8.3Identification, segregation, dispositionCorrective Action8.5.2Root cause, implementation, verificationPreventive Action8.5.3Risk identification, implementation

### Related Skills

SkillIntegration Pointquality-manager-qmrManagement review, quality policycapa-officerCAPA system managementqms-audit-expertAdvanced audit techniquesquality-documentation-managerDHF, DMR, DHR managementrisk-management-specialistISO 14971 integration
## Trust
- Source: tencent
- Verification: Indexed source record
- Publisher: alirezarezvani
- Version: 2.1.1
## Source health
- Status: healthy
- Source download looks usable.
- Yavira can redirect you to the upstream package for this source.
- Health scope: source
- Reason: direct_download_ok
- Checked at: 2026-04-23T16:43:11.935Z
- Expires at: 2026-04-30T16:43:11.935Z
- Recommended action: Download for OpenClaw
## Links
- [Detail page](https://openagent3.xyz/skills/quality-manager-qms-iso13485)
- [Send to Agent page](https://openagent3.xyz/skills/quality-manager-qms-iso13485/agent)
- [JSON manifest](https://openagent3.xyz/skills/quality-manager-qms-iso13485/agent.json)
- [Markdown brief](https://openagent3.xyz/skills/quality-manager-qms-iso13485/agent.md)
- [Download page](https://openagent3.xyz/downloads/quality-manager-qms-iso13485)